Averill Park & the Capital Region, NY 24/7 emergency service · Licensed & insured

Weil-McLain certified · upstate New York

Weil-McLain commercial boiler startup and service

There is one factory-certified Weil-McLain startup and service provider in upstate New York. We start up and commission new plants, keep existing ones running and take care of warranty work, on every Weil-McLain model.

Certified by Weil-McLain for upstate New York

Trinity Plumbing & Drains is the only Weil-McLain factory-certified startup and service provider in upstate New York. Our technicians are trained by Weil-McLain on its equipment and work to its startup and service procedures.

A careful startup is what lets a new boiler reach the efficiency it was bought for. It also leaves the owner with recorded readings to measure every future service visit against.

Who calls us

  • Mechanical contractors who need a certified startup before a job can close out
  • Engineers who want a plant commissioned to Weil-McLain's procedure
  • Facility managers at schools, offices and municipal buildings
  • Multifamily owners replacing boilers or adding capacity

What we do

From first fire to the yearly service

Need a startup booked for a handover date? Send the details and we will work back from it.

  • Startup

    A walk-through of the gas supply, venting, piping and condensate lines before anything fires. Then first fire, gas pressure and combustion set with an analyzer, and every safety and limit control tested. The results go to you as a written startup report.

  • Commissioning

    Controls set up for the building: setpoints, outdoor reset and the firing sequence across multiple boilers. Where a building management system is involved we work alongside the controls contractor, and we take the building staff through the plant before handing it over.

  • Service and repair

    Planned maintenance, combustion testing and troubleshooting on running plants, whoever installed them.

  • Warranty work

    Covered failures on Weil-McLain equipment are diagnosed and repaired by us as warranty work.

Commercial models

Weil-McLain commercial boilers we start up and service

Condensing, stainless steel firetube and sectional cast iron gas boilers, for hot water and steam.

  • Weil-McLain

    SlimFit

    Type
    Commercial condensing gas boiler
    Heat exchanger
    Cast aluminum sections
    Input
    550–2,000 MBH
    Application
    Hot water
    Venting
    Category II / IV; PVC, CPVC, PP, ABS or AL29-4C (by model)
    • Sectional design suits cast iron upgrades to high efficiency
    • No rigging: built-in roller casters and shipping ramp
    • Fits through a standard door; left- or right-hand orientation
    Weil-McLain's spec sheet for the SlimFit
  • Weil-McLain

    SVF

    Type
    Stainless steel firetube gas boiler
    Heat exchanger
    Stainless steel vertical firetube
    Input
    500–3,000 MBH
    Efficiency
    96–98% thermal (by model)
    Application
    Hot water
    Venting
    3-in-1 vent adapters; 4″–10″ (by model)
    • Sizes: 500–600, 725–850, 1000 and 1500–3000 MBH
    • Up to 10:1 or 12:1 turndown; 160 psi max working pressure
    • Built-in roller casters and shipping ramp
    • Color touchscreen controls with enhanced diagnostics
    Weil-McLain's spec sheet for the SVF
  • Weil-McLain

    LGB Series 3

    Type
    Commercial cast iron gas boiler
    Heat exchanger
    Cast iron
    Input
    350–2,470 MBH
    Efficiency
    84% thermal (water); 81% thermal (steam)
    Application
    Hot water and steam
    Venting
    Quick-connect draft inducer
    • Horizontal cast iron section heat exchanger
    • Ships knocked down, as an assembled block or fully packaged
    • Job-site assembly suits tight boiler rooms
    • Upgraded controls with enhanced diagnostics
    Weil-McLain's spec sheet for the LGB Series 3
  • Weil-McLain

    LGB Series 2

    Type
    Commercial cast iron gas boiler
    Heat exchanger
    Cast iron
    Input
    400–2,860 MBH
    Application
    Hot water and steam
    Venting
    Natural draft
    • Short draw rods for faster section assembly
    • Factory-assembled base and burners
    • Compact design leaves more piping and venting headroom
    • Built-in air separator
    Weil-McLain's spec sheet for the LGB Series 2
  • Weil-McLain

    Evergreen Pro Series 2

    Type
    Condensing gas boiler, light commercial
    Heat exchanger
    Stainless steel fire tube
    Input
    110–399 MBH
    Efficiency
    95% AFUE (110–299); 96.5% combustion (399)
    Application
    Hot water
    Venting
    3″ or 4″ vent (by model)
    • Modbus connection to a building management system
    • ZoneStacking: up to 24 programmable zones
    • Controls up to 8 boilers with lead/lag rotation
    Weil-McLain's spec sheet for the Evergreen Pro Series 2
  • Weil-McLain

    80 Series 1

    Type
    Commercial cast iron gas boiler
    Heat exchanger
    Cast iron
    Input
    346–1,674 MBH
    Efficiency
    80.2–80.7% thermal (gas, by model)
    Application
    Hot water and steam
    Venting
    Field-convertible flue
    • Knocked down or packaged, for water or steam
    • Jacket side panels lift off without tools
  • Weil-McLain

    88 Series 2

    Type
    Commercial cast iron gas steam boiler
    Heat exchanger
    Cast iron
    Input
    1,010–5,845 MBH
    Efficiency
    83.1% thermal (gas)
    Application
    Steam
    • On/off, low/high or full modulation firing
    • Packaged or knocked down
    • 24–145 boiler horsepower
    • Single or multiple boiler systems
  • Weil-McLain

    88 Series 3

    Type
    Commercial cast iron gas boiler
    Heat exchanger
    Cast iron
    Input
    960–5,440 MBH
    Efficiency
    84% thermal (sizes 488–888, gas)
    Application
    Hot water
    • Wide, open waterways forgiving of older plant water
    • Knocked down, assembled block or fully packaged
    • Heavy-duty design for long service life
  • Weil-McLain

    94 Series 3

    Type
    Commercial cast iron gas boiler
    Heat exchanger
    Cast iron
    Input
    2,540–8,660 MBH
    Efficiency
    80.7–83.8% thermal, water (gas, by model)
    Application
    Hot water and steam
    Venting
    Forced draft
    • Water circulates fully around the combustion area
    • All heating surfaces cleanable from one side
    • Gastight sections with patented sealing rope
    • Simplified piping: no return header

Select a product to see its main specs. Product images courtesy of Weil-McLain. Weil-McLain and its product names are trademarks of WM Technologies LLC.

Where we work

Across upstate New York

Weil-McLain's certification for us covers upstate New York. We run out of Averill Park, east of Albany, and plan visits further afield around the job and the handover date.

General commercial plumbing is handled by our sister company, Trinity Commercial

A Weil-McLain boiler at home?

Installs, repairs, tune-ups and warranty work on house boilers are on their own page.

Weil-McLain boilers for homes

Boilers of any make

Questions

Commercial Weil-McLain work

Why have a factory-certified technician start up a Weil-McLain commercial boiler?

Startup is when the gas pressure, combustion and controls are set for the building the boiler actually sits in. Done to Weil-McLain's procedure by a technician it has trained, the plant runs the way it was specified, and the readings on the startup report become the baseline every later service visit is checked against.

Which Weil-McLain models do you work on?

All of them. We start up and service every Weil-McLain model, from a wall-hung Evergreen on a light commercial job to a sectional cast iron plant assembled in the boiler room.

Will you service a Weil-McLain plant another contractor installed?

Yes. Maintenance, repairs and warranty work are the same whoever put the boilers in.

How do we book a startup?

Call (518) 348-3032 or use the form on this page. Send the boiler model, how many boilers there are, the site address and the date you are working towards. We reply with a date and a short list of what has to be in place on site first.

Do you travel outside the Capital Region?

Our certification covers upstate New York. We are based in Averill Park, east of Albany; for a site further out, call and we will plan the visit around the job.

Book it

Schedule a Weil-McLain startup or service visit

Tell us the model, how many boilers, the site and your target date. We call back to confirm and to quote the work.

(518) 348-3032

Weil-McLain startup or service

Leave your details and we will call back to set a date.

Step 1 of 2

Your name

Plant down in a cold snap? Call now.

Our line is answered 24 hours a day, for buildings as well as homes.